- cGMP regulations require a laboratory test to ensure that components, containers and closures, in-process materials, and finished products meet specifications, including stability testing specifications.
- According to the USFDA, in order to confirm the OOS root cause, the OOS must be thoroughly investigated, unbiasedly, and with sound scientific justification.
- Certain checklists must be verified in order to meet regulatory requirements and conduct a thorough investigation. Laboratory investigation, manufacturing investigation, and warehouse investigation should be used as checkpoints.
- A result that is out of specification (OOS) is one that does not conform or meet the manufacturer's or laboratory's predetermined limit or acceptance criteria.
- A result that is out of specification (OOS) is one that does not conform to or meet the manufacturer's or laboratory's predetermined limit or acceptance criteria.
- Laboratory investigation
- Manufacturing investigation
- Warehouse investigation
- Analyst errors
- Instrument/Equipment errors
- Laboratory System errors
Analyst
Errors |
Yes |
No |
NA |
Weighing and measurement errors (sample weight & measurement |
|
|
|
Calculation errors (and raw data completeness) |
|
|
|
Analytical errors related to dilutions, mobile phases, filters,
chromatography, conditions, and so forth. |
|
|
|
Analyze the critical steps that were followed during the analysis |
|
|
|
The reference/working standard used in the analysis is correct |
|
|
|
Assay value and storage condition are determined correctly for the
reference/working standard |
|
|
|
Check the appearance, potency, expiry date, and LOD/water mentioned. |
|
|
|
Whether the test solution(s) are properly prepared |
|
|
|
During preparation, any loss of standard solution or test solution |
|
|
|
Other analytical techniques were not properly applied during the test |
|
|
|
If any unusual or unexpected effect is observed for standard or test
preparation (e.g. If equipment is contaminated by a previous sample) |
|
|
|
Whether any alternate validated method is used for the analysis |
|
|
|
If the analyst is qualified |
|
|
|
Is the analyst trained to carry out the test? |
|
|
|
Whether the environmental conditions are suitable for the test |
|
|
|
Cleaning of glassware and calibration status |
|
|
|
Analyst Qualification |
|
|
|
Instrument/Equipment
Errors |
Yes |
No |
NA |
Analytical equipment (including glassware) that didn’t work or was not
calibrated was used in the analysis. |
|
|
|
Verify if the system meets the requirements for RSD, resolution
factor, and / or other criteria. |
|
|
|
Ensure that the chromatographic analysis does not include any
out-of-limit parameters. |
|
|
|
Column used is correct |
|
|
|
This column has been used previously |
|
|
|
Instrument/equipment calibration status |
|
|
|
Instrument/Equipment preventive maintenance |
|
|
|
Laboratory
System Errors |
Yes |
No |
NA |
Confirm
that the analyst understands the test method; discuss the test method with
the analyst. |
|
|
|
A trained
analyst should be familiar with the instrument/ equipment and maintain the
records |
|
|
|
Schedule of
calibrations |
|
|
|
Solutions
shelf life |
|
|
|
Calibration
procedure and test method |
|
|
|
Working
standard qualification |
|
|
|
Efficiency
of columns |
|
|
|
Environmental
conditions |
|
|
|
Documentation |
Yes |
No |
NA |
Write/
transfer error |
|
|
|
Calculation
error |
|
|
|
Carrying out |
Yes |
No |
NA |
Carrying
out |
|
|
|
Incorrect
procedure |
|
|
|
Standard |
Yes |
No |
NA |
Correct
standard |
|
|
|
Expiration
date |
|
|
|
Storage |
|
|
|
Initial
weight |
|
|
|
Dilution |
|
|
|
Sample |
Yes |
No |
NA |
Correct
standard |
|
|
|
Storage |
|
|
|
Initial
weight |
|
|
|
Dilution |
|
|
|
- Manufacturing investigation checklists include:
- Equipment errors
- Operator errors Production system errors
Equipment
Errors |
Yes |
No |
NA |
Is the equipment specified and validated? |
|
|
|
Is there any malfunctioning of the equipment? |
|
|
|
Are there any power
outages for extended periods during manufacturing? |
|
|
|
Operators
Errors |
Yes |
No |
NA |
Do operators trained on the equipment |
|
|
|
Did the operator make any
errors (wrong weight, wrong material, incorrect sequence of additions)? |
|
|
|
Interview with the operator |
|
|
|
Production
System Errors |
Yes |
No |
NA |
Are there any deviations from cGMP/SOP? |
|
|
|
Is the process validated? |
|
|
|
Does the specified environmental condition apply? |
|
|
|
Is the standard Master
Formula followed? |
|
|
|
Are correct sampling procedures followed? |
|
|
|
Do batch production records have the correct entries and standard
manufacturing procedures is followed? |
|
|
|
Is there a change in the blend time or dry time? |
|
|
|
During processing, was there any spillage of material? |
|
|
|
Does the environment meet the specified conditions? |
|
|
|
Are all steps of the manufacturing process carried out within the
approved timeframe? |
|
|
|
The manufacturing process aspects that may be responsible for the
problem are listed here. |
|
|
|
When storage containers are at different stages of manufacturing,
whether they are stored appropriately in designated locations. |
|
|
|
Describe how long the containers are stored at various stages. |
|
|
|
Are yields in the previous and next batch within acceptable limits? |
|
|
|
Make sure the yield is reconciled at each stage. In case the yield
exceeds the standard, explain why. |
|
|
|
Does documentation of the process is reviewed? |
|
|
|
If you have any other observations, record them. |
|
|
|
3. Warehouse Investigation Checklist
Warehouse
Investigation |
Yes |
No |
NA |
Did the material come from an approved vendor? |
|
|
|
Do RM/PM stores maintain their storage conditions? |
|
|
|
Do the dispensing
operators are trained? |
|
|
|
Are the materials used as
described in the bill of materials? |
|
|
|
Do physical stock and written quantity match for used material? |
|
|
|
Have previous and next
batches been dispensed with proper line-clearance procedures? |
|
|
|
Are the materials dispensed within the validated time before
manufacturing begins? |
|
|
|