Which of the following is not true about High-pressure liquid chromatography (HPLC)?
- It requires high pressure for the separation of the specious
- There is no need to vaporize the samples
- It is performed in columns
- It has high sensitivity
High-pressure liquid chromatography can be performed only in columns.
- True
- False
Which of the following is not an advantage of Syringe-type pumps used in High-pressure liquid chromatography?
Which of the following is not true about solvent programming which is done in high-performance liquid chromatography?
- It provides unequal bandwidth.
- It provides fast overall separation.
- It provides maximum resolution.
- It provides maximum sensitivity.
Which of the following pulse dampers takes up some amount of the pulsation energy that is released to provide smooth pressure without pulsations?
- Flexible bellows or compressible gas passed through tee columns
- Flexible inert diaphragm
- Electronic pulse damper
- Electrical pulse damper
Which of the following is not a characteristic of the syringe pump used in high-pressure liquid chromatography?
- Pressure capability is high
- Maintenance is frequent
- Limited reservoir capability
- Slight change in flow rate when extremely high pressure compresses the solvent
Syringe pumps used in High-pressure liquid chromatography are most suitable for which of the following columns?
- Capillary columns
- Guard columns
- Short-fast columns
- Small bore columns
The gravity feed method for solvent delivery is not used with narrow bore columns packed with fine mesh particles.
- True
- False
Which of the following cannot be done to reduce ripple in High-pressure liquid chromatography?
- Using bellows
- Using restrictors
- Using long nylon tube between pump and column
- Avoiding the use of the solvent pump
Which of the following is not true about Hydraulic capacitance flow control system used in HPLC?
- It can be used only for liquids with low viscosity
- It is irrespective of solvent compressibility
- It maintains a constant flow
- It smoothens high pressure pump pulsations
Derivatization techniques in HPLC are intended to enhance
- Molecular weight
- Reversibility
- Detectability
- Reproducibility
In HPLC, the analytical performance improves when
- Particle diameter in increased
- Particle diameter is reduced
- Coarser particles are paired with shorter columns
- Low temperature is used
What is the nature of mobile phase in reverse phase chromatography?
- Polar
- Non polar
- Mixture of both
- Can be any it depends on the nature of analyte
Solvent programming, also called gradient elution, involves:
- Changing the column length
- Using the mobile phase composition
- Successive injection of sample
- Changing the mobile phase composition
The pressure used in HPLC is:
- 1000-3000 psi
- 1000-5000 psi
- 2000 to 6000 psi
- 1000 to 6000 psi
ALSO READ: Peak Purity and Peak Identification
An essential requirement of the mobile phase in HPLC is that:
- It must have constant flow rate with pulses
- It must run at 20°C only
- It must be freshly distilled
- It must flow with pulses
HPLC is an abbreviation for
- High Profit Liquid Chromatography
- High Pressure Liquid Chromatography
- Higher Performance Low Chromatography
- Higher Profit Low Chromatography
In reverse phase chromatography, the stationary phase is made
- Non-polar
- Polar
- Either non-polar or polar
- None of these
Derivatization techniques in HPLC are intended to enhance
- Molecular weight
- Detectability
- Reversibility
- Reproducibility
Indicate the HPLC detector that is most sensitive to change in temperature:
- PDA detector
- Refractive Index detector
- Fluorescence detector
- Electrochemical detector
Which of following HPLC detectors is not a solute property detector?
- UV–Visible detector
- Photo diode array detector
- Fluorescence detector
- Refractive index detector
Which of following HPLC detector is a bulk property detector?
- Refractive index detector
- UV detector
- Photo diode array detector
- Fluorescence detector
For amino acid analysis by HPLC derivatization reagent used by UV absorption detector is
- 4-Nitrobenzyl-N-propylamine hydrochloride
- 4-Nitrobenzyloxyamine hydrochloride
- 3,5-Dinitro benzoyl chloride
- 4-Nitrobenzyl-N-N’-disopropylisourea
In HPLC the analytical performance improves when
- Particle diameter is increased
- Particle diameter is decreased
- Coarser particles are paired with shorter columns
- Low temperature is used
RP-HPLC method contains
- Stationary phase is polar and mobile phase is non-Polar
- Stationary phase is non-polar and mobile phase is polar
- Stationary phase is non-polar and mobile Phase is non-polar
- Stationary phase is polar and mobile phase is polar
ALSO READ: Understanding of HPLC Audit Trails
1. 2 | 2. 1 | 3. 4 | 4. 1 | 5. 1 |
6. 2 | 7. 4 | 8. 1 | 9. 4 | 10. 1 |
11. 3 | 12. 2 | 13. 1 | 14. 4 | 15. 4 |
16. 1 | 17. 2 | 18. 1 | 19. 2 | 20. 2 |
21. 4 | 22. 1 | 23. 3 | 24. 2 | 25. 2 |